FCCC LOGO Faculty Publications
Wilson SK , Parker J , Carrion R , Simhan J
Out of place cylinders discovered in the postoperative period
Int J Impot Res. 2021 Jan;33(1) :43-48
Back to previous list
Abstract
If the surgeon makes a flawed and unrecognized movement with an instrument during implantation surgery, the cylinder subsequently may migrate into an unexpected position with inflation and thrusting post operatively. The out of position cylinder is now evident to the patient or symptomatic with discomfort. This 5th Wilson's Workshop will describe our recommended surgeries for correction of out of place cylinders and illustrate the simplest, safest and least invasive.
Notes
1476-5489 Wilson, Steven K Parker, Justin Carrion, Rafael Simhan, Jay Journal Article Review England Int J Impot Res. 2021 Jan;33(1):43-48. doi: 10.1038/s41443-020-0310-0. Epub 2020 May 26.