Lattice_grid_med
Powered by LatticeGrid

Search Enter term and hit return. Use '*' for as a wildcard.
Yeh KA, Biade S, Lanciano RM, Brown DQ, Fenning MC, Babb JS, Hanks GE, Chapman JD
Polarographic Needle Electrode Measurements of Oxygen in Rat Prostate Carcinomas - Accuracy and Reproducibility
International Journal of Radiation Oncology Biology Physics (1995) 33:111-118.
Abstract
Purpose: The oxygenation status of tumors may be important for predicting tumor response to therapy. Previous studies with the (a)naplastic (R3327-AT) and well-differentiated (R3327-H) Dunning rat prostate tumors using indirect assays of tumor oxygenation indicated the relative hypoxic and radioresistant nature of the anaplastic tumor. We now report direct measurements of oxygen in these tumors made with the pO(2) histograph to determine: (a) whether a significant difference in oxygenation status could be detected between them; (b) whether sequential measurements on the same tumor gave similar values; and (c) whether tumor oxygenation correlated with tumor volume. Methods and Materials: R3327-AT and R3327-H tumors were grown in Fischer X Copenhagen rats to volumes of 1.0-7.0 cm(3). Electrode measurements (100-200) were made in tumors in anesthetized animal along two parallel tracks. Repeat measurements were made at 1-5 days along different parallel tracks. Oxygen partial pressures of muscle tissue were measured and served as a normal tissue control. Statistical analyses were applied to determine whether tumor oxygen levels were different between the two tumor histologies, whether sequential measurements in the same tumor were reproducible, and whether tumor oxygenation correlated with tumor volume. Results: The average median pO(2) of the well-differentiated (n = 15) and the anaplastic (n = 15) tumors was 6.0 mmHg (SE +/- 1.3) and 2.2 mmHg (SE +/- 0.3), respectively. The average median pO(2) of normal rat muscle (n = 15) was 23.6 mmHg (SE +/- 2.0). These values represent highly significant differences in oxygen concentration between the two tumors and rat muscle. The differences in average mean pO(2) values were also highly significant. Repeat measurements in the same tumors on different days gave average median values of 4.7 and 2.2 mmHg in the R3327-H (n = 15) and R3327-AT (n = 15) tumors, respectively. For these repeat measurements, median pO(2) values decreased in 15 and increased in 15 tumors, and were not significantly different from the first measurements. The average differences observed in median pO(2) were 37% (SE +/- 7) and 58% (SE +/- 10) for the R3327-H and R3327-AT tumors, respectively. No significant correlation was observed between pO(2) levels and the tumor volumes investigated in this study. Conclusions: The median pO(2) values of the anaplastic I)Dunning tumors were significantly Lower than those of the well-differentiated tumors (p < 0.001). Oxygen levels in both tumors were significantly lower than those measured in normal rat muscle (p < 0.00005). Repeat measurements of median pO(2) in the same tumors were not significantly different for either tumor model (p > 0.5). The changes observed in pO(2) distributions within individual tumors from day to day may indicate true dynamics of its oxygenation status and/or the limits of electrode measurements, by sampling along only two insertion sites. The electrode measurements of pO(2) in these tumor models are reproducible and confirm previously detected oxygenation differences between the anaplastic and well- differentiated tumors.
Note
Publication Date: 1995-08-30.
Back
Last updated on Saturday, August 22, 2020